1. Basic Function Interface
① Waveform Display Area:Records, stores, and deletes waveform data, including voltage and current. When viewing a single waveform, you can zoom in and out using the mouse scroll wheel.
② Output Voltage and Current Settings: Change the output voltage and current values of the current preset group (changes are temporary and not saved; the device will revert to initial values after reboot).
③ Data Group Data: Click on a data group to set preset voltage and current values. Up to 6 different preset values can be saved.
④ Measurement Switch: Measures output capacity and energy. Measurements are reset upon closing and reopening.
⑤ Brightness Settings: 14 levels (Higher level means brighter backlight).
⑥ USB Interface: Product Model / Firmware Version / Communication Rate / Communication Port / Device Address / Online Status
⑦ Basic Information: Input Voltage / Output Voltage / Output Current / Output Power / Temperature
Display / Status Display
Control Device On/Off Status On This Interface

Basic Function Interface
2. Advanced Function Interface
① Sequential Output: Within the specified range of sequence numbers and loop counts,
sequentially output voltage and current parameters.
Click "Start" to execute sequential output (other interfaces are locked and inactive). Numbers
that have been executed show "OK", while numbers that haven't been executed show "Waiting".
Click "Pause" to maintain the current sequence output. Click "Continue" to execute subsequent
steps according to the set delay.
Manual Mode: Click "Single Step" for testing, testing proceeds according to the number of clicks.
Stopping will maintain the current sequence output.
② Current Sweep: With fixed voltage, the current is scanned and output within the set range
according to the step current and delay, commonly used in constant current mode. Voltage
setting needs to be greater than 0V; Starting current, ending current range: 0.000A5.000A (if the
starting and ending values are the same, it's invalid); Step current range: 0.001A5.000A; Delay
time: 1s~86400s. Click "Start" to execute current scanning output (other interfaces are locked
and inactive). Click "Stop" to stop the scan and close the output.
③ Voltage Sweep: With fixed current, the voltage is scanned and output within the set range
according to the step voltage and delay, commonly used in constant voltage mode. Current
setting needs to be greater than 0A; Starting voltage, ending voltage range: 00.00V30.00V (if the
starting and ending values are the same, it's invalid); Step voltage range: 00.01V30.00V; Delay
time: 1s~86400s. Click "Start" to execute voltage scanning output (other interfaces are locked
and inactive). Click "Stop" to stop the scan and close the output.

Advanced Function Interface
3. PC Software Connection
① Turn on the device and connect it to the computer using a Micro data transfer cable.
② After connection, select the communication port. You can view it through Device Manager in
Computer Management.
③ Click "Connect". Once "Connected" is displayed in the left text box, the connection is successful.
※ NOTE: During the PC software connection process, the device buttons will be locked and cannot
be operated.